Installation & Operation Manual
KBVF SERIES
Variable Speed / Soft-Start AC Motor Drive
with Electronic Motor Overload Protection*
Rated for 208-230 and 400/460 Volt 50 & 60 Hz
3-Phase & PSC** AC Induction Motors from 2 thru 5 HP
Operates from 208/230 Volt and 400/460 Volt 50/60 Hz AC Line Input***
See Safety Warning,
on page 8.
Note: The drive is factory set for
60 Hz motors. For 50 Hz motors,
see Section 6.1, on page 14.
The information contained in this manual is intended to be accurate. However, the manufacturer retains
the right to make changes in design which may not be included herein.
*UL approved as an electronic overload protector for motors. **Custom software is required for PSC motors.
See PSC Motor Addendum (Part No. A42142). ***Do not use this drive with GFCIs. Special software is available –
contact our Sales Department. ****Installation of a CE approved RFI filter is required.
© 2006 KB Electronics, Inc.
(see back cover)
A Complete Line of Motor Drives
Chassis/IP-20 AC Drives
****
This Manual Covers Models KBVF-27, 29, 45, 48
L3
W
L1
AC LINE
L2
VUTB1
MOTOR
50/60HzJ2
CON3
CON1
J1
X1 X2
A/M
CL MAX MIN ACC COMPDEC/B
Vue de la page 0
1 2 3 4 5 6 ... 28 29

Résumé du contenu

Page 1 - KBVF SERIES

Installation & Operation ManualKBVF SERIESVariable Speed / Soft-Start AC Motor Drivewith Electronic Motor Overload Protection*Rated for 208-230 an

Page 2

3.2 PERFORMANCE FEATURES•Power Start™ – Provides more than 200% starting torque which ensures startup of highfrictional loads.•Slip Compensation with

Page 3 - UL Notice

• DIVF – Modbus Communication Module (Part No. 9568) – Allows the drive to communicate withPLCs, PCs, and HMIs with Modbus RTU protocol utilizing a se

Page 4 - MAXCL ACCMIN DEC/B COMP

built-in cooling fan on this end31.812.70.5(8 Places)5.10.2(Models KBVF-45, 48)217Models KBVF-29, 48 contain a76.21.253.00178(Models KBVF-27, 29)1917.

Page 5

4 IMPORTANT APPLICATION INFORMATION4.1 MOTOR WITH EXTERNAL FANCOOLING – Most totally enclosed fan-cooled (TEFC) and open ventilated 3-phase AC inducti

Page 6

level of 160% of the rated drive current. The CL Trimpot is used to recalibrate the drive current from60% thru 200%. The Power Start™ circuit provides

Page 7

6.1.2 Setting the Drive for TwoTimes the Rated Motor RPM –The drive can also be used tooperate the motor up to twotimes the rated RPM. However,constan

Page 8

The enclosure should be large enough to allow for proper heat dissipation so that the ambient temperaturedoes not exceed 45 °C (113 °F). Leave enough

Page 9

9 WIRING INSTRUCTIONSWARNING! Read Safety Warning, on pages 8 and 9, before using the drive. Disconnectmain power when making connections to the drive

Page 10

9.3 MOTOR CONNECTION – Wire the motor toTerminals “U”, “V”, “W”. The terminals are locatedon the upper PC board. See Figure 14, on page17. Motor cable

Page 11 - TABLE 2 – ELECTRICAL RATINGS

9.5 SIGNAL FOLLOWING CONNECTIONS – Thedrive output will linearly follow the analog signalinput.Models KBVF-27, 29Wire the isolated* 0 – 5 Volt DC sign

Page 12

TABLE OF CONTENTSSection Page1 Quick-Start Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 13 - Adjustable Trimpots

9.6 MANUAL START SWITCHCONNECTION (CON1) – TheManual Start Mode is used tomanually start the drive or restartthe drive (reset) if a fault hasoccurred.

Page 14 - Z AND 50 HZ MOTOR OPERATION

9.9 RUN/FAULT RELAY– The Run/FaultRelay is built-in onModels KBVF-45, 48and optional onModels KBVF-27,29. The Run/FaultRelay OutputContacts are locate

Page 15 - FIGURE 11 – AUTOMATIC START

10 AC LINE FUSINGThis drive does not contain AC line fuses. Most electrical codes require that each ungrounded conductorcontain circuit protection. Do

Page 16 - AC KILOVOLTS

12.1 POWER ON (PWR) – The “PWR” LED will illuminate green when the AC line is applied to the drive.12.2 STATUS LED (ST) – The “ST” LED is a tricolor L

Page 17 - MOTOR AC LINE

on page 24.13.3 ACCELERATION (ACC) – Sets the amount of time for the motor toaccelerate from zero speed to full speed. The ACC Trimpot is factoryset t

Page 18 - (Supplied) (Front View)

13.6 BOOST (DEC/B) – When the drive is set for 50 Hz MotorOperation (Jumper J1 installed in the “50Hz” position), theDEC/B Trimpot automatically becom

Page 19 - Volts DC

Note: This adjustment must be made within 6 seconds orthe I2t Trip will occur.1. Connect an AC RMS ammeter in series with one motorphase.2. Set the CL

Page 20 - F - S - R

– NOTES –27

Page 21 - - S - R

LIMITED WARRANTYFor a period of 18 months from the date of original purchase, KB Electronics, Inc. will repair or replacewithout charge, devices which

Page 22 - STATUS LED INDICATOR

RECONDITIONING THE BUS CAPACITORS If this drive has been in storage for over one year it is necessary to recondition the power supply bus capacitors.

Page 23

TABLE OF CONTENTS (Continued)Figures Page29 SIVFR Offset Trimpot (OFFSET) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24

CON1CON2CON3X1 X2J2A/MF - S - RPWRST P3P2J1P150/60HzMAXCL ACCMIN DEC/B COMPMain Speed Potentiometer (5 k)see Section 9.4, on page 18.(Supplied) (Front

Page 25

Ground (Earth):Motor Connection:see Section 9.2, on page 17.see Section 9.3, on page 18.3-Phase Connection:AC LineMotorL3WL1AC LINEL2VUTB1MOTOR50/60

Page 26

Signal Input, Direction Switch, and Main Speed Potentiometer connections.Sets the drive for operation with a voltage or current input signal.Sets the

Page 27 - – NOTES –

1 QUICK-START INSTRUCTIONS7See Figures 1 – 3, on pages 4 – 6. Also see Section 4 — Important Application Information, onpages 13 and 14.WARNING! Disco

Page 28 - KB ELECTRONICS, INC

Models KBVF-45, 48Unidirectional Speed Operation – Wire the potentiometer to Terminals “+5V” (high), “SIG1” (wiper),“COM1” (low), of Terminal Block TB

Page 29

3INTRODUCTIONThank you for purchasing the KBVF Adjustable Frequency Drive. KB Electronics, Inc. is committed to pro-viding total customer satisfaction