17
FIGURE 11
UNIDIRECTIONAL PRESET FREQUENCY SELECTION
WITH 2-WIRE START/STOP CONNECTIONS
Note: Use Function Nos. 7.07 – 7.13 to program the desired Preset Frequencies.
TABLE 5
UNIDIRECTIONAL PRESET FREQUENCY SELECTION
WITH 2-WIRE START/STOP PROGRAMMING
Function No. Code/Range
1.00: Run/Stop-Forward/Reverse Control 0001: External Contacts
3.00: Stored Set Frequency 00.00 Hz
7.00: Multi-Function Input Terminal 1 0000: Preset Frequency Operation*
7.01: Multi-Function Input Terminal 2 0001: Preset Frequency Operation*
7.02: Multi-Function Input Terminal 3 0002: Preset Frequency Operation*
7.04: Multi-Function Input Terminal 5 0010: N.O. Start*
*Factory setting.
FIGURE 12
UNIDIRECTIONAL PRESET FREQUENCY SELECTION
WITH 3-WIRE START/STOP CONNECTIONS
Note: Use Function Nos. 7.07 – 7.13 to program the desired Preset Frequencies.